Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM06261
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/15/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) STRAP REAR PORCH, TIE DBL PLATES TO EACH GLUE LAM STRAP MIDDLE COL. TO TRUSS 2) NEED FLASHING BACKING FRONT AND REAR 3) FINISH NAILING HANGERS AT EACH LEDGER 4) TWO NAILS IN EACH WIND BRACE AT PLATES |