Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM06255

Parcel: 136126920


Addresses:

9840 E DOMENIC LN

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
01/25/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
01/23/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE PAGE S-1
2) FOOTINGS NEED TO BE 19" WIDE
3) ALTERNATE VERTS AND SUPPORT VERTICAL REBAR PRIOR TO POUR
4) VERTICAL REBAR TO BE 48" ON CENTER AND EACH SIDE OF EVERY OPENING