Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM06210
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ANCHOR BOLTS SOUTH SIDE GARAGE WALL/WHERE STUD BREAKS OVER PLATE WITHIN 12"-ALSO NAIL STUD 2) MISSING LTHJ HANGER AT ENTRANCE HIP 3) NEED A35 CLIPS AT PATIO JOIST 2 PLACES 4) 2ND FLOOR H.D. MISSING LHJ HANGER 5) MISSING HUS26 HANGER 2ND FLOOR-BALLOON OVER GARAGE 6) A35 MISSING NAILS AT TRUSS BEDROOM #2 SOUTH WALL 7) ROOF OVER GARAGE NEEDS MORE NAILS 8) NO LADDER TO INSPECT REST OF ROOF |