Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06CM06206
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/09/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* USE TEF TAPE ON EXTERIOR CLEANOUTS |
|
07/26/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - NEED TO TERMINATE CLEANOUTS W/APPROVED ADAPTORS AND PLUGS AT GRADE LEVEL. - C O IN CONCRETE REQUIRES FRANK PATTERN COVER - ALL CO PLUGS SHALL BE WATER & GAS TIGHT - THIS PERMIT IS FOR EXTERIOR UTILITIES ONLY - GAS, WATER, WASTE AND VENT PIPING INSIDE BUILDING REQUIRES PERMITS ALSO. - PVC AND PE PIPING ARE NOT APPROVED UNDER BUILDING - YOUR PLAN FOR THIS WORK HAS NOT BEEN APPROVED - THE WORK IS NOT INSTALLED PER YOUR PLAN - PIPING UNDER BUILDING IS NOT PROPERLY SUPPORTED. |
|
01/18/2007 | PLUMBING - FINAL | Not ready for Inspection | NEED TO SEE SEWER CLEANOUTS TERMINATED, MAKE WATER AND GAS TIGHT. ALSO, NEED TO SEE STATE APPROVAL OF INTERIOR GAS PIPING OR NEED TO INSPECT INTERIOR GAS PIPING W/TEST FOR UTILITY CLEARANCE. |
|
01/16/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |