Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM06206
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/09/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
07/10/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ALL PLUMBING CONNECTIONS TO EJECTOR TANK OK TO COVER |
|
01/16/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CORRECT SLOPE AT 3" VENT, TRANSITION TO C1 BELOW GRADE, ABS CANNOT BE EXPOSED TO SUN SUPPORT ABS AND CORRECT SLOPE AT EJECTOR DO NOT TEST PLASTIC W/AIR - SAFETY HAZARD TEST PVC WATER LINE W/WATER |