Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM06162
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
04/23/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CLOSET FLANGES OK 2) NEED TO SEE FROM EXTERIOR STUB UP THRU MANIFOLD IN FIRE RISER ROOM ON WATER DISTRIBUTION |
|
01/29/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV THRU ROOF ALL AREAS OK 2) WATER DISTRIBUTION OK 3) EXCEPT FROM EXTERIOR STUB UP ON EXTERIOR TO MANIFOLD IN ROOM ( FIRE RISER ROOM ) 4) NEED TO SEE CLOSET FLANGES PRIOR TO SETTING STOOLS ON FINISH FLOORING + |
|
01/27/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE TUB DRAIN AND OVERFLOW CORRECTLY & PROVIDE TEST ON TUB PIPING 2) ALL VENTS IN RETURN AIR PLENIUM TO BE NON-COMBUSTIBLE MATERIAL WITH TEST THRU ROOF 3) PROVIDE LONG RADIUS DRAINAGE FITTING ON TUB DRAIN ARM |
|
11/24/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV THRU ROOF RESTROOM 104 WITH DRINKING FOUNTAIN, RECEPTION 102, MENS RESTROOM 120, WOMENS RESTROOM 121, STORAGE 122, DRINKING FOUNTAIN 101. WATER DISTRIBUTION SAME AREAS WATER TEST OK |
|
10/27/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE TEST ON ALL PIPING AND UNDERGROUND PIPING 2) PROVIDE SUPPORT ON ALL PIPING IN WALL AND ABOVE CEILING 3) INSTALL ALL PIPING PER APPROVED PLANS 4) PROVIDE CLEANOUTS PER UPC 2006 |