Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/07/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WRONG PLAN ON SITE PLAN REQUIRED T05M0154 PLAN ON SITE JOB M0250 |
|
| 02/28/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SW4 REQUIREMENTS PER TABLE 602.10.5 STATE THAT AN 8 FOOT WALL NEEDS 24" BRACED WALL PANELS WITH A 65 PERCENT MAX OPENING HEIGHT (LESS THAN ?" ). AS BUILT HAS 18" BRACED WALL PANELS WITH 84" OPENING ON LOWER SECTION, UPPER SECTION IS 10 FEET TALL WITH 18" BWP 2) PLEASE SUBMIT APPROVED ENGINEER REPAIR |
|
| 02/26/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE SW4 SOUTH SIDE |