Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM06100
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/09/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER SUBJECT TO PETITION OF APPEAL FOR T&P |
|
05/04/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. TEST ON TUB WASTE OK 2. SHOWER VALVES DO NOT MEET REQUIREMENTS OF SEC 420 UPC 3. ALSO, IF MIXING DISSIMILAR METALS ACCESS IS REQUIRED PER SEC 311.6 4. PROVIDE ACCESS AT SHOWER VALVES OR ELIMINATE THE COPPER. 5. WATER PIPING NOT PER PLAN SEC. 605.3 REQUIRES SEPARATE SHUT OFF VALVES FOR EACH RESIDENCE. 6. PIPE T&P TO EXTERIOR AT NEW WH. PER SEC. 608.5 |
|
05/01/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
04/30/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. OWNER HAS DECIDED NOT TO RELOCATE LAV OR W.H 2. PRESSURE BALANCED SHWR VALVE REQUIRED AT NEW TUB/SHWR 3. FILL TUBS W/WATER FOR RUN TEST |