Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/27/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* REPLACE DAMAGED CO PLUGS SEAL W/APPROVED THREAD SEALANT |
|
| 07/25/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - SWEEP REQUIRED ON VENT BELOW FLOOD LEVEL AT AAV UNIT #2 - CLEANOUT PLUGS SHALL BE WATER & GAS TIGHT - CLEANOUT PLUGS SHALL BE LISTED TO RECEIVE SCREW - HAMMER ARRESTORS REQUIRED AT WB 609.10 SHOWER HEADS LEAK - REMOVE EXCESS FLUX AT T&P - CAP HW OUTLET UNDER KS |
|
| 07/20/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS PRIOR TO CALLING FINAL EXPOSE COVERED WORK FOR INSPECTION |