Permit: T06CM06086

Parcel: 10703141D

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/02/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
02/27/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE FRESH AIR INTAKES.
2. PERMANENTLY I.D ALL EQUIPMENT. NO INK.
3. PROVIDE MIN. 1/8" PER FT. SLOPE ON CONDENSATE DRAIN.
4. PROVIDE SCREENS IN T-TOPS.
5. RELOCATE GAS SHUT OFF VALVES UPSTREAM OF THE GAS FLEX CONNECTOR.
6. PROVIDE GFI SERVICE RECEPTACLES WITHIN 25' OF ALL EQUIPMENT.
7. ROOF DRAIN CANNOT TERMINATE INTO THE DRY WELL.
8. PROVIDE AIR BALANCE REPORT
9. CONDENSATE FROM 2 UNITS NOT TERMINATED.