Permit: T06CM06081

Parcel: 116300180

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/19/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/15/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED BY OWNER
10/19/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 10 NAIL TOP/TOP PLATE 6" ON CENTER PER SHEAR PANEL 4 AT STUDY
2) RETROFITS REQUIRED GARAGE HOLDOWNS UNDER WINDOWS WEST WALL
3) NAIL OSB TO TOP/TOP PLATE GARAGE SOUTHWALL
4) MISSING COIL STRAP PER DETAIL 13/6 REAR PORCH
5) REAR PORCH APPROVED PLAN 2 X 10 NOT PER PLAN. REVISE PLAN OR BUILD TO PLAN
6) APPROVED PLAN DOES NOT SHOW ADDED WINDOWS MASTER SUITE
7) RETRO FIT HOLDOWN REQUIRED BEDROOM 3. ALL HOLDOWNS MUST BE ATTACHED DBL STUDS
8) NAIL ALL HOLES HOLDOWN FRONT PORCH
9) MISSING HOLDOWN FRONT PORCH
10/12/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
10/09/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. DETAIL 2/6 MISSING A/35 & A.3 AT LEDGER
2. GABLE END RIDGE NAILERS MISSING AT PER
DETAIL 6/6 & LTP4
3. MISSING H2.5 AT HEADER PER HEADER SCHEDULE
4. CLIPS MISSING PER DETAIL 14/6
5. MISSING HOLDDOWNS AT FAMILY ROOM AND FOYER
6. CHANGE OSB SHEAR AT GUEST WALLS TO FULL SHEATS
7. NAILING OF HOLDDOWN MUST BE CONTINUOUS ON 2X4 STUDS
8. NEED TRUSS CALCS LAYOUT IS OFF AT GUEST BEDROOM
MORE THAN 24" AT ENTRY
10/05/2007 EXT METAL CLIPS/EXT SHEATHING Cancelled IVRS - RI canceled