Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM06080
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/26/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SMALL PIECE OF ROOF DECK NOT NAILED EAST SIDE FRONT 2) WRONG SIZE NAILS IN P.A.'S 3) NAIL PANELS TO ROOF 4) THE ONLY EXT. SHEAR TRANSFER I CAN FIND IS O.S.B. UP TO TOP CHORD 5) NAIL ALL STUDS VERTICALLY THAT ATTACH TO P.A.'S 6) WEST SIDE DBL GIRDER TO BEAR ON 2-2 X 12 HEADER |