Permit: T06CM06034

Parcel: 116300240

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
01/11/2008 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
01/10/2008 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOT READY
11/20/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) PARTIAL 22/6 RETAINING WALLS ONLY PER REVISION
2) WALLS ONLY PER REVISION
3) OK TO POUR FOOTERS 1/6 GARAGE, DINING, MASTER BED AND BATH
11/14/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH REVISED DETAIL 22/6
2) FOOTERS TO BE MINIMUM 16" INTO UNDISTURBED SOIL
3) #4 AT 24" ON CENTER ALTERNATE BENDS