Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM06032
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
12/20/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) NEEDS CERTS ONLY-ALL ELSE OK |
|
12/18/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO POST TENSION TAG 2) FILL HOLE IN PANEL 3) BACK DOOR RECEPTACLE NOT GFI AND BALCONY 4) VACUUM BREAKER HOSE BIBS 5) NEED DRIP LEG ON GAS AT FURNACE 6) RECEPTACLE LEFT OF STOVE NOT GFI 7) EXPOSED LAMPS NOT PERMITTED IN CLOSETS 8) RECEPT AT A/C NOT GFI 9) CONNECT WATER HEATER |