Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/29/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
|
| 01/26/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* WILL REQUIRE FULL SIZE CLEANOUT AT BRANCH |
|
| 01/24/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. WILL REQUIRE CLEAN-OUTS ON ALL BRANCH PIPING OVER FIVE FEET FROM MAIN. 2. PLUMBERS TAPE NOT APPROVED STRAP 3. SUPPORT ABS PER 2003 UPC TABLE 3-1 NOTE: PLAN CALLS FOR PVC WILL REQUIRE LETTER OF ACCEPTANCE FOR ABS. 4. SUPPORT TRAP ARM 5. OK TO INSULATE HOT PIPING 6. ABS SHIMS NOT APPROVED SUPPORT. |