Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM05999
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/29/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
06/28/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL LUGGING OF NEUTRAL NOT ALLOWED 2) DBL LUGGING 12 & 14 ON SAME LUG NOT ALLOWED 3) NO DIELECTRIC ALUMINUM 4) WHITE WIRES CANNOT BE HOT 5) FLOURESCENT LIGHTS CANNOT BE WITHIN 6" HORIZONTALLY OF CLOSET SHELVES |