Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/07/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
|
| 05/02/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* NO CHANGE FROM LAST INSPECTION |
|
| 04/30/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP. 2. A TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEG. WITHOUT ADDITIONAL CLEANOUT 3. ABS IS TO BE SUPPORTED MID-STORY VERTICALLY AND AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS. |
|
| 04/27/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 04/24/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |