Permit: T06CM05973

Parcel: 105102420


Addresses:

455 E WETMORE RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/11/2007 PLUMBING - INTERMEDIATE Approved
08/17/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
COMPLETE WORK FROM PANEL INSPECTIONS LIST
BEFORE CALLING FOR INSPECTION
08/02/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
08/01/2007 PLUMBING - INTERMEDIATE Not ready for Inspection REQUIRE PLANS, PERMIT AND PREVIOUS INSPECTION HISTORY PRIOR TO FINAL INSPECTION
04/03/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/02/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NO HEAT TRAPS AT W.H
1. CLOSET FLANGE TO BE SET 1/4" ABOVE FINISHED FLOOR
2. WATER HEATER MAY NOT BE SOLE SOURCE OF HEAT CONTROL AT PUBLIC USE LAVATORIES.
03/30/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. WATER CLOSET SET BEFORE FLANGE WAS APPROVED
2. PLUMBERS TAPE NOT AN APPROVED STRAP
3. BACKPITCH ON VENT NOT APPROVED
4. WATER SERVICE DROP NOT SUPPORTED
5. SEE DETAIL #5 MPH1
6. NO CLEANOUT ON SINK
03/23/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. CLOSET FLANGE TO BE RESET
2. HORIZ X HORIZ CHANGE OF DIRECTION TO BE A SWEEP
3. OK TO INSULATE HOT
4. SUPPORT VERTICAL & HORIZONTAL PIPING
5. OK TO COVER WALLS