Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 06/29/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LIGHT AT PANTRY 6" FROM SHELVING 2) TERMINATE ROMEX AT EAVE INTO BOX/FIXTURE 3) NEED GFCI PROTECTION ON ALL EXTERIOR RECEPTACLES ACCESSIBLE 4) NEED A RECEPTACLE AT KITCHEN WALL BEHIND STOVE NOT ACCESSIBLE 5) SEDIMENT TRAP AT WATER HEATER 6) NEED TO BE DOWN STREAM OF SHUT OFF VALVE 7) INSTALL DISHWASHER/DRAIN LOOP 8) SEDIMENT VALVE AT FURNACE ON WRONG SIDE OF SHUT OFF VALVE 9) PROVIDE GFCI PROTECTION AT RECEPTACLE ON ROOF AT A/C UNIT 10) SECURE CONDUIT AT A/C DISCONNECT AND BOX LOOSE |