Permit: T06CM05964

Parcel: 105120530


Addresses:

4009 N STONE AV #01


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T06CM05964

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/10/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
08/09/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
BOTH UNITS
1. PANEL DIRECTORY NOT CORRECT -- NEC 408.4
2. EXTERIOR RECEPTACLE NOT ALLOWED ON BATHROOM RECEPTACLE CKT -- NEC 210.11B3

UNIT 1
1. BEDROOM (WEST) SMOKE DETECTOR NOT INTERCONNECTED
08/06/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PARTIAL INSPECTION ONLY -- CHECK BOTH UNITS

ON ROOFTOP
1. INSTALL PROPER SIZE FUSES
2. CONDENSATE DRAIN NOT TO RUN IN FRONT OF DISCONNECT
3. IDENTIFY WHITE USED AS HOT
4. W.P COVERS NOT ABLE TO CLOSE
5. STRAP FLEX WITHIN 12" OF TERMINATIONS
6. LAUNDRY RECEPTACLE NOT WORKING
7. KITCHEN SWITCH UPSIDE DOWN
8. DISPOSAL RECEPTACLE SET BACK
9. NEED GFI PROTECTION FOR KITCHEN COUNTER RECEPTACLES
10. REFER RECEPTACLE HAS REVERSE POLARITY

CHECK PANEL DIRECTORIES - CORRECT, NEAT, LEGIBLE