Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM05942
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/16/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. AT FRONT HIP GARAGE, SHEETRS RUN LONG DIMENSION BLK 4'0" EDGE. 2. MISSING HANGERS AT GARAGE TRUSSES 3. NEED A 3.5 'S AT GARAGE FLUSH HEADER BEHIND SHEAR NAIL O.S.B ROOF DECKING TO LEDGER SAME PLACE 4. HINGE BRACES NOT INSTALLED PER PLAN 5. NEED X-BRACES AT EA. END FOR ROTATION 6. WRONG NAILS IN REAR P.A'S 7. RAT RUN COL TRUSS 8. MINIMUM 10D COMMONS IN HANGERS AT GARAGE 9. BEARING SHIMS ALL TRUSSES AT GARAGE E02 C03'S |