Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM05942

Parcel: 141316750


Addresses:

7804 E JACK OAK RD

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/16/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/09/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. AT FRONT HIP GARAGE, SHEETRS RUN LONG DIMENSION BLK 4'0" EDGE.
2. MISSING HANGERS AT GARAGE TRUSSES
3. NEED A 3.5 'S AT GARAGE FLUSH HEADER BEHIND SHEAR NAIL O.S.B ROOF DECKING TO LEDGER SAME PLACE
4. HINGE BRACES NOT INSTALLED PER PLAN
5. NEED X-BRACES AT EA. END FOR ROTATION
6. WRONG NAILS IN REAR P.A'S
7. RAT RUN COL TRUSS
8. MINIMUM 10D COMMONS IN HANGERS AT GARAGE