Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM05930
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/10/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED DETAIL FOR PORCH, FRAMING NOT ON PLAN |
|
| 01/05/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 6' 2 X 4 AT 6' ON CENTER MISSING PER 2/SD4 2) LSL MISSING PER 17/SD4 3) HORIZONTAL STRAP MISSING PER 9/SD2 4) 3" ON CENTER STAGGERED NAIL PATTERN REQUIRED OVER SHEARWALLS PER 18/SD4 5) CS20 STRAP REQUIRED FROM ENTRY GLU LAM TO TRIMMERS PER 9/SD2 6) GLU LAM AT STAIRWAY NOT PER PLAN-NEED STRAPS AND POSTS PER 9/SD2 7) PORCH BEAMS NOT TIED DOWN 8) TWO TRIMMERS REQUIRED AT 2 X 12 HDR IN DEN 9) STOPPED INSPECTION-BUILD PER PLAN |