Permit: T06CM05909

Parcel: 128030110


Addresses:

5704 E BROADWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/22/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/18/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTE #1 FROM 1/16/07 INSPECTION
COMPLY WITH THIS REQUIREMENT OR YOU SHALL
BE REFEED - PLANS CALLS FOR 1" INSULATION.
01/16/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NOTE: SEE YOUR SHOCK STOP INSTALLATIONS INSTRUCTIONS
HORIZONTAL OR VERTICAL INSTALLATION ONLY?

1. ALL INSULATION SHALL BE INSTALLED PER MANUFACTURE INSTALLATION INSTRUCTIONS. JOINTS TO BE SEALED WITH GLUE & RAGGING TAPE. INSULATION TO BE FULLY SURROUNDING PIPING & SEALED PROPERLY. SEE NOTE #17 PAGE P-4 FOR REQUIREMENTS.
01/11/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WASTE & VENT THRU ROOF WATER TEST OK
WATER PIPING OK
1. COMPLETE INSULATION ON ALL HOT & HOT RETURN PIPING AND PROVIDE SAFETY PLATES WHERE WITHIN 1 1/4" OF FACE OF STUD. PLUMBING OK TO DRYWALL AFTER ITEM #1
2. SHALL SEE COMPLETION OF EXISTING LAV FOR ADA ACCESS
3. CLOSET FLANGES REQUIRED TO BE 1 1/4" TOP OF FLANGE TO FINISH FLOOR SURFACE & SECURED TO FLOOR WITH WATER RESISTANT SCREWS - SEE INSTALLATION STANDARD #5 2003 UPC
4. ALL QUICK ACTING WATER VALVES REQUIRE WATER HAMMER ARRESTOR DEVICES
EXAMPLE: WASHING MACHINE, FLUSH VALVES, SELENOID VALVES, DISHWASHER, ETC.