Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM05820
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/09/2007 | FRAMING | Approved | IVRS - Inspection :* | |
03/08/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIX STUD IN NORTH EAST SHEARWALL OF GARAGE |
|
02/26/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS FROM PREVIOUS INSPECTION OF 02/20/07 HAVE NOT BEEN CORRECTED |
|
02/20/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL ALL HOLES IN TOP PLATES 2) REMOVE OSB BOARD ON STUDS AT GARAGE-IF TWISTED FIX IT RIGHT 3) SEAL WEEP SCREED 4) NO WATER TEST 5) NO DWV TEST 6) BLOCK MECHANICAL DUCT VENTS 3 SIDES 7) CHASE AT BOTTOM STAIRWAY MISSING FIRESTOP 8) NAILS ON SHEATHING HEADER 9) NAILS ON STAIRWAY HEADER 10) INSULATE AROUND WINDOW FRAMES 11) REPLACE OSB BOARD BACK ON SHEARWALL-WHERE CUT FOR TUB |