Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/01/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT EXTERIOR PLUMBING 2) PLAN DOES NOT SPECIFY FIRST TO SECOND FLOOR TIE IN SUBMIT DETAIL 1/S3.0 AND 2/S3.0 3) MANY HOLDOWNS MISSING PER PLAN RETROFITS REQUIRED 4) ALL ROOF PANELS MUST SPAN 3 BAYS OR 2 TRUSSES. REPLACE PANELS OR BLOCK 24" ON CENTER NAIL |
|
| 02/28/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING BLOCKING PER DETAIL 2/S3.0 GARAGE SOUTH WALL 2) MISSING SW-1 PANEL UPSTAIRS CLOSET 3) NAIL TOP PLATE SW-1 KITCHEN 4) MISSING SW-2 PANEL KITCHEN 5) NAIL PROTECT PLUMBING 6) MISSING BLOCKING PER DETAIL 2/S3.0 BED 3 7) STOPPED INSPECTION |
|
| 02/27/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* INCOMPLETE |