Permit: T06CM05793


Addresses:

50 N ALVERNON WY


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T06CM05793

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
07/06/2007 REINFORCED MASONRY PRE-GROUT Approved MASONRY PRE-GROUT COMPLETE
TRASH CONTAINER AREA; SCREEN WALL @ PARKING LOT
ALL WALLS 6' --
07/05/2007 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
LOBBY ENTRY WALLS @ 16'8"; TOPPED OUT & CAP
OK TO GROUT
07/03/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MAIN ENTRY LOBBY WALLS @ 16'4" OK TO GROUT
07/02/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH LOBBY WALL @ 16'4" -- OK TO GROUT
06/29/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
E & W WALLS @ ENTRY AREA @ 12'4" -- OK TO GROUT
06/28/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
06/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MAIN ENTRY ARCH AREA @ NORTH WALL - 21' LOBBY AREA WALLS @ 8'4" -- OK TO GROUT PROGRESS AREAS
06/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LOBBY ENTRANCE 2ND LIFT @ 8'
N.WEST CORNER;
NORTHWALL @ 18'4" OK TO GROUT
06/25/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NW WALL; NORTH WALL NE WALL - ALL @ 12'-14';
LOBBY AREA @ 0'-4' -- OK TO GROUT PROGRESS AREAS
06/22/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NE PORTION @ 14' -- OK TO GROUT; SE & SW CORNERS TOPPED OUT/CAPPED @ 16'4"
06/21/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SE & SW CORNERS @ 12' TO 16' AS PER DETAIL #201 & 202
NORTH & NE WALL @ 8' TO 12' --- OK TO GROUT
06/20/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR NEEDS RFI FOR LINTELS ON
NORTH & NORTHEAST WALLS - WILL RECALL
06/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SE CORNER @ 12' -- OK TO GROUT
06/18/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL @ 8'; NW PORTION @ 8'; NE PORTION @ 8'
SE SECTION @ 8'; GROUTED; SW CORNER 8-12 OK TO GROUT
06/15/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) N.E. SECTION AT 8' GROUT FOR DOOR JAMBS OK TO GROUT
06/14/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) S.E. CORNER AT 8'-S.W. CORNER AT 8'; WEST, N.W. AND N AT 4' OK TO GROUT WALLS
06/13/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST, SOUTH AND SOUTHWEST EXTERIOR WALLS AT 4' OK TO GROUT
05/31/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
STEM WALL @ 16" - POURED - CONTINUOUS WALLS