Permit: T06CM05789

Parcel: 110160460


Addresses:

5991 E GRANT RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM05789

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/17/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/28/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
PROTECT ABS RE-VENT FROM SHARP EDGE OF STUD
OK TO COVER AFTER CORRECTING
CLOSET FLANGES OK IF NO TILE
09/27/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DWV TEST OK
INSTALL SAFETY PLATES
CU TOUCHING METAL
CLOSET FLANGES SECURED TO CONCRETE FLOOR, WILL INSPECT FLANGES AFTER FLOOR IS FINISHED.
09/26/2007 PLUMBING - INTERMEDIATE Denied - COPPER TOUCHING METAL, ALSO PROTECT CU FROM STUCCO AT SERVICE, SECURE OVERHEAD COPPER
- LEAK ON DWV
- SAFETY PLATES
- BACKING FOR MS FAUCET, T&P DRAIN
- CHECK YOUR WORK PRIOR TO INSP
- SECURE FLANGES TO FINISHED FLOOR
09/21/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
DWV N/R
AT DOMESTIC WATER SERVICE, PROVIDE SEPARATION FROM EXTERIOR WALL AND FROM METAL
SECURE AND SUPPORT PIPING