Permit: T06CM05775

Parcel: 113043310

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/14/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) PLAN CALLS FOR CPVC-YOU INSTALLED PEX. PLAN CALLS FOR PVC WASTE-YOU INSTALLED ABS. PROVIDE STAMPED LETTER FROM J.A.C.A. ACCEPTING MATERIAL TYPE, AND YOU ARE OK TO COVER-SUBJECT TO THAT APPROVAL
2) REPLACE ABS SECTION BETWEEN TWO N/H SECTION, AND REPLACE WITH CAST IRON
3) OK TO COVER ALL AREAS
05/02/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. NOT INSTALLED PER PLAN
NO REDLINES ON SITE
INSTALLATION NOT PER CODE
MAY NOT DUMP A DRAIN INTO A VENT
EXISTING SERVICE SINK DOES NOT EXIST