Permit: T06CM05764

Parcel: 141330840


Addresses:

8410 S GUPTA DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM05764

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/16/2007 FRAMING Approved IVRS - Inspection :*
04/13/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REPLACE BROKEN STUD UPSTAIRS BEDROOM
2. REPLACE STUD AT HALL BATH
04/09/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPLACE OVERNOTCHED STUDS AT COMBUSTION AIR VENTS
2) HALL BATH-REPLACE CUT STUD OVER PLUMBING
3) NEED TO CAULK AROUND HOSE BIB AT PATIO
4) REBAR FOR UFER OUTSIDE OF WALL
5) PROTECTION PLATE GARAGE SHEARWALL PLUMBING
6) PROTECTION PLATES NEEDED ON PLUMBING AT 1 1/2 OR LESS KITCHEN, BATHROOMS
7) NO DWV TEST
8) NO WATER TEST
9) B-VENT NEEDS TO TERMINATE BELOW LID
10) BLOCK DUCT VENT 3 SIDES AT DEN AND UPSTAIRS
11) FIRESTOP AT CHASES
12) STOPPED INSPECTION-REFUSED TOO DO PUNCH LIST