Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/13/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REPLACE BROKEN STUD UPSTAIRS BEDROOM 2. REPLACE STUD AT HALL BATH |
|
| 04/09/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPLACE OVERNOTCHED STUDS AT COMBUSTION AIR VENTS 2) HALL BATH-REPLACE CUT STUD OVER PLUMBING 3) NEED TO CAULK AROUND HOSE BIB AT PATIO 4) REBAR FOR UFER OUTSIDE OF WALL 5) PROTECTION PLATE GARAGE SHEARWALL PLUMBING 6) PROTECTION PLATES NEEDED ON PLUMBING AT 1 1/2 OR LESS KITCHEN, BATHROOMS 7) NO DWV TEST 8) NO WATER TEST 9) B-VENT NEEDS TO TERMINATE BELOW LID 10) BLOCK DUCT VENT 3 SIDES AT DEN AND UPSTAIRS 11) FIRESTOP AT CHASES 12) STOPPED INSPECTION-REFUSED TOO DO PUNCH LIST |