Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM05763

Parcel: 117020440


Addresses:

501 E 1ST ST #02


Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Permit Number - T06CM05763

Inspection Description - STEM WALL/RETAINING WALL

Inspection Status - Approved

Date Description Inspector Results Comments
06/20/2008 STEM WALL/RETAINING WALL Approved
11/15/2007 STEM WALL/RETAINING WALL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TOE DOWN AT GARAGE DOOR OPENING, NEEDS MORE ANGLE
2) PLUMBING IN FOOTERS NEEDS TO BE RE-WRAPPED AND PROTECTED
3) POST FOOTING AT PATIO MISSING REBAR
4) NEED TO CLEANOUT ALL LOOSE DIRT IN FOOTINGS
5) PEX LINE IN FOOTER BY PATIO IS IT WATER SUPPLY LINE ?