Permit: T06CM05750

Parcel: 141330720


Addresses:

8451 S OTIS DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM05750

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/05/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/04/2007 EXT METAL CLIPS/EXT SHEATHING Denied 1) TIGHTEN BOLTS AT ALL H.D.'S
2) REPLACE CUT O.S.B. BOARD AND BLOCK WEAK POINT AT PORCH
3) NEED TO FASTEN WITH SCREWS 2ND FLOOR
01/03/2007 EXT METAL CLIPS/EXT SHEATHING Denied 1) MAIN ROOF OK
2) PORCH (REAR) WEAK SPOT OSB BLK BELOW
3) FRONT 1/2 OF 2ND FLOOR NOT FASTENED
4) NAIL ALL SHEAR WALL BOTTOM PLATES 6" ON CNETER 16D'S
5) 2 PLACES ON ROOF NEED SUPPORT FROM BELOW ONE SPOT AT FRONT HIP PEAK AT RIDGE ONE BAY OSB TURNED WRONG WAY NORTH SIDE OF RIDGE
12/28/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) INSTALL AND ATTACH ALL H/D'S
2) 1 SHEET MISSED B02 TRUSS WEST SIDE