Permit: T06CM05709

Parcel: 140552460

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/29/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/28/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TRUSS NOT REPAIRED PER REPAIR DOCUMENT
2) TRUSS REPAIR DOCUMENT MUST HAVE THIS ADDRESS ON IT AND BE APPROVED BY CITY OF TUCSON
3) FIRE STOP CHASE IN GARAGE
4) BLOCK DUCT BOOTS 3 SIDES
5) STAIRS EXCEED 3/8" DIFFERENCE IN RISE
6) NO DWV WATER TEST
7) 6/SD3 REQUIRED AT GARAGE #2 SHEARWALL
8) GARAGE SHEARWALL 7 NOT NAILED PER PLAN
12/27/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER JJ
12/11/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) WAITING ON FIX FOR BROKEN TRUSS
12/08/2006 EXT METAL CLIPS/EXT SHEATHING Denied 1. NEED DBL STUD AT SHEAR WALL CORNERS AT GARAGE.
2. NEED A STRAP AT PLUMBING REAR BOTTOM PLATE.
3. NEED NUT & WASHER 2 PLCS PATIO
4. NEED DBL STUD AT DBL GIRDER GARAGE
5. JOIST HANGERS AT GARAGE
6. DIAGONAL BLOCK MISSING PER 1/SD4 - WILL SHEAR W/OSB NAILED W/8D SD4
7. GARAGE H.D NOT INSTALLED
8. BROKEN TRUSS
9. EDGE NAILING NEED 8D NOT STAPLES