Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRUSS NOT REPAIRED PER REPAIR DOCUMENT 2) TRUSS REPAIR DOCUMENT MUST HAVE THIS ADDRESS ON IT AND BE APPROVED BY CITY OF TUCSON 3) FIRE STOP CHASE IN GARAGE 4) BLOCK DUCT BOOTS 3 SIDES 5) STAIRS EXCEED 3/8" DIFFERENCE IN RISE 6) NO DWV WATER TEST 7) 6/SD3 REQUIRED AT GARAGE #2 SHEARWALL 8) GARAGE SHEARWALL 7 NOT NAILED PER PLAN |
|
| 12/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JJ |
|
| 12/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) WAITING ON FIX FOR BROKEN TRUSS |
|
| 12/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1. NEED DBL STUD AT SHEAR WALL CORNERS AT GARAGE. 2. NEED A STRAP AT PLUMBING REAR BOTTOM PLATE. 3. NEED NUT & WASHER 2 PLCS PATIO 4. NEED DBL STUD AT DBL GIRDER GARAGE 5. JOIST HANGERS AT GARAGE 6. DIAGONAL BLOCK MISSING PER 1/SD4 - WILL SHEAR W/OSB NAILED W/8D SD4 7. GARAGE H.D NOT INSTALLED 8. BROKEN TRUSS 9. EDGE NAILING NEED 8D NOT STAPLES |