Permit: T06CM05700

Parcel: 140180700

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/14/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/11/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. USE CORRECT FITTINGS FOR SEAL TITE ON ROOF FOR GFI OUTLETS - REPAIR SEAL TITE PULLED OUT OF FITTING.
2. SEE NOTE #2 LAST INSPECTION
3. UNIT #1 LOCKED AND APPEARS TO BE OCCUPIED A REINSPECTION FEE WILL BE ASSESSED NEXT INSP. IF NO COMPLIANCE - UNITS SHOULD NOT BE OCCUPIED PRIOR TO INSP. APPROVALS.
06/01/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GFI PROTECTED RECEPTS REQUIRED ON ROOF FOR AC MAINT.
2. ARC FAULTS MUST PROTECT ALL OUTLETS IN BEDROOMS, INCLUDES LIGHTS & SMOKE DETECTORS. ALSO, SMALL CAN LIGHTS IN BEDROOMS NOT WORKING.
3. COULD NOT LOCATE PLANS.