Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/11/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/09/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK WALLS, CEILINGS, WILL CHECK SWITCH GROUNDS AT FINAL 2) BE ADVISED THAT ALL BEDROOM OUTLETS INCLUDING LIGHTS AND SMOKE DETECTORS TO BE ON ARC FAULT CIRCUIT BREAKER |
|
| 04/05/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEE NOTE #2 INSP. ON 3/30/07 2. PLANS? 3. ALL LIGHT SWITCHES TO BE GROUNDED |
|
| 04/04/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : There is no access to the site.| 920* UNIT LOCKED |
|
| 03/30/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. CABLE SHEATH MUST BE 1/4" INSIDE OF BOX FEEDERS AT SERVICE 2. ROMEX CONNECTORS REQUIRED FOR TERMINATIONS INTO PANELS. 3. INSTALL NAIL PLATES ABOVE PANELS. |