Permit: T06CM05687

Parcel: 133243720

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM05687

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/12/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/03/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. DWV OK
2. INSULATION ON WATER PIPING IS TO BE INSTALLED PER MANUFACTURE SPECS WHICH REQUIRES JOINTS TO BE SEALED W/ADHESIVE.
3. OK TO COVER WALLS AFTER CORRECTING INSULATION.
4. DON'T FORGET MOP SINK BACKING
5. CLOSET FLANGES SHALL BE SECURED TO FINISHED FLOOR W/FASTENERS WITH TOP OF FLANGE 1/4" ABOVE FINISHED FLOOR PER UPC IS #5
12/29/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*