Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM05687
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/12/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
01/03/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. DWV OK 2. INSULATION ON WATER PIPING IS TO BE INSTALLED PER MANUFACTURE SPECS WHICH REQUIRES JOINTS TO BE SEALED W/ADHESIVE. 3. OK TO COVER WALLS AFTER CORRECTING INSULATION. 4. DON'T FORGET MOP SINK BACKING 5. CLOSET FLANGES SHALL BE SECURED TO FINISHED FLOOR W/FASTENERS WITH TOP OF FLANGE 1/4" ABOVE FINISHED FLOOR PER UPC IS #5 |
|
12/29/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |