Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* TRASH ENCLOSURE @ 8' -- BOND BEAM WITH #4 CONTINUOUS OK TO GROUT & CAP |
|
| 08/28/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TRASH ENCLOSURE @ 4' OK TO GROUT |
|
| 06/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL MASONRY WALLS COMPLETE @ DETERMINED HEIGHT AS PER PLANS. | |
| 06/04/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE H/2.8 TO H/2.9 @ 14'8" TO 28'4" OK TO GROUT |
|
| 06/01/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL; ENTRY AREA - 4' ABOVE STEEL BEAM LINE H/2 TO H/2.8 EAST WALL TOPPED OUT -- OK TO GROUT |
|
| 05/31/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL @ 34'8" -- LINE F/1 TO G/1 OK TO GROUT & CAP |
|
| 05/30/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL @ 32' -- LINE D/1 TO G.5/1 OK TO GROUT |
|
| 05/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH WALL @ 34'8" LINE B/1 TO B/1.5 EAST WALL @ 32' LINE B/1 TO D1 SW TOWER @ 32' OK TO GROUT |
|
| 05/25/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SW TOWER @ 28' EAST WALL @ 28'4" LINE B/1 TO NORTH WALL @ 30'5" LINE B/1 TO B/1.5 G.5/H OK TO GROUT |
|
| 05/23/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL @ 24' LINE C/1 TO E/1; SW TOWER @ H/3 @ 24' -- OK TO GROUT |
|
| 05/22/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH WALL 28' A.F.F.E GRID 1-2/A WEST WALL A-C/1 24' A.F.F.E SOUTH WALL G/1-2 TOPOUT |
|
| 05/18/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL LINE A TO H @ 20' - N.WALL B/1 TO B/1.75 @ 24' B/2 TO B/3 TOPPED OUT SW ENTRY COLUMN @ 20' OK TO GROUT |
|
| 05/16/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL @ 16'; NORTH WALL EXCEPT FOR NW PORTION @ 19'6" SOUTH WALL MID PORTION @ 19'6" OK TO GROUT |
|
| 05/14/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL @ 13' -- OK TO GROUT |
|
| 05/10/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL @ 8'; SOUTH WALL @ 14'8" UP TO ENTRY AREA WEST WALL @ 14'8" NORTH WALL 14'8" TO 16' -- OK TO GROUT |
|
| 05/04/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH - SOUTH - WEST WALLS @ 12' OK TO GROUT |
|
| 05/01/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH, SOUTH, WEST EXTERIOR WALLS @ 8' OK TO GROUT |
|
| 04/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PERIMETER WALLS @ 4' OK TO GROUT |