Permit: T06CM05679

Parcel: 12218258C


Addresses:

3731 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
08/29/2007 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
TRASH ENCLOSURE @ 8' -- BOND BEAM WITH #4 CONTINUOUS
OK TO GROUT & CAP
08/28/2007 REINFORCED MASONRY PRE-GROUT Partial Approval TRASH ENCLOSURE @ 4'
OK TO GROUT
06/05/2007 REINFORCED MASONRY PRE-GROUT Partial Approval ALL MASONRY WALLS COMPLETE @ DETERMINED HEIGHT AS PER PLANS.
06/04/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE H/2.8 TO H/2.9 @ 14'8" TO 28'4" OK TO GROUT
06/01/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH WALL; ENTRY AREA - 4' ABOVE STEEL BEAM
LINE H/2 TO H/2.8
EAST WALL TOPPED OUT -- OK TO GROUT
05/31/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST WALL @ 34'8" -- LINE F/1 TO G/1 OK TO GROUT & CAP
05/30/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST WALL @ 32' -- LINE D/1 TO G.5/1
OK TO GROUT
05/29/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL @ 34'8" LINE B/1 TO B/1.5
EAST WALL @ 32' LINE B/1 TO D1
SW TOWER @ 32' OK TO GROUT
05/25/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SW TOWER @ 28'
EAST WALL @ 28'4" LINE B/1 TO NORTH WALL @ 30'5" LINE B/1 TO B/1.5 G.5/H OK TO GROUT
05/23/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST WALL @ 24' LINE
C/1 TO E/1; SW TOWER @ H/3 @ 24' -- OK TO GROUT
05/22/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL 28' A.F.F.E GRID 1-2/A
WEST WALL A-C/1 24' A.F.F.E
SOUTH WALL G/1-2 TOPOUT
05/18/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST WALL LINE A TO H @ 20' - N.WALL B/1 TO B/1.75 @ 24'
B/2 TO B/3 TOPPED OUT
SW ENTRY COLUMN @ 20' OK TO GROUT
05/16/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST WALL @ 16'; NORTH WALL EXCEPT FOR NW PORTION
@ 19'6" SOUTH WALL MID PORTION @ 19'6" OK TO GROUT
05/14/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST WALL @ 13' -- OK TO GROUT
05/10/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST WALL @ 8'; SOUTH WALL @ 14'8" UP TO ENTRY AREA
WEST WALL @ 14'8"
NORTH WALL 14'8" TO 16' -- OK TO GROUT
05/04/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH - SOUTH - WEST WALLS @ 12'
OK TO GROUT
05/01/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH, SOUTH, WEST EXTERIOR WALLS @ 8'
OK TO GROUT
04/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PERIMETER WALLS @ 4'
OK TO GROUT