Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/10/2007 | PLUMBING - GAS PRESS TEST FNL | Approved | IVRS - Inspection :* | |
| 10/09/2007 | PLUMBING - GAS PRESS TEST FNL | Partial Approval | IVRS - Inspection :* 1. SAFETY CABLES NOT TO BE INSTALLED ON GAS PIPING FASTENER TO WALL 2. GAS PRESSURE TEST OK |
|
| 09/26/2007 | PLUMBING - GAS PRESS TEST FNL | Partial Approval | IVRS - Inspection :* TEST THRU ANSUL TO ALL APPLIANCES VALVES (OK) 1. SHALL PROVIDE SAFETY CABLES & QUICK DISCONNECT FOR GAS APPLIANCES ON WHEELS. 2. NEW WATER HEATER REQUIRES TEMPERATURE & PRESSURE RELIEF DRAIN PIPING, USE APPROVED MATERIAL, GRAVITY DRAIN TO DAYLIGHT TERMINATING AT 90 DEG. DOWN 6" - 24" FROM FINISH GRADE |