Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/26/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1. NAIL ROOF MARK BELOW ON FLR 2. RE-NAIL 2ND FLR. DECK NOT NAILED PER PLAN 6" X 12" 3. BLK. OSB TURNED WRONG WAY FRONT EYE BROW CHECK AT INTERMEDIATE OK TO LATHE, DRY-IN ROOF |
|
| 12/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FLR/DECK NAIL PER SCHEDULE 6" EDGE 12" FIELD 10D'S 2) NAIL ALL SHEAR PANELS HORIZONTAL JOINTS 3) BLK OSB AT FRONT ROOF, POP OUT 24" ON CENTER OSB TURNED WRONG DIRECTION 4) MISSED NAILING ON BOTH SIDES OF ROOF, MARKED IN BACK |