Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM05647
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/12/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
01/04/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 3 AND 5 FROM PREVIOUS 2) ROOF SHEATHING MUST SPAN 3 MEMBERS 3) NAIL ROOF SHEATHING TO BIRD BLOCKS |
|
12/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) TRUSS A03 MISS TRUSS BRACES 2) TRUSS A04 MISSING H2.5 CLIPS MID PT 3) SC03 TRUSS NOT BEARING ON BEARING POINT. PROVIDE CITY APPROVED TRUSS ENGINEERING REPAIR 4) TRUSS ?C01M MISSING TRUSS BRACING 5) NAIL DBL STUDS WITH HOLDOWN WITH EDGE NAILING SCHEDULE 6) A04D MISSING H.25 CLIP 7) NO LADDER ACCESS TO ROOF 8) 5/DT1 REQUIRES X BRACE AT 48" ON CENTER |