Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/12/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/04/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 3 AND 5 FROM PREVIOUS 2) ROOF SHEATHING MUST SPAN 3 MEMBERS 3) NAIL ROOF SHEATHING TO BIRD BLOCKS |
|
| 12/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) TRUSS A03 MISS TRUSS BRACES 2) TRUSS A04 MISSING H2.5 CLIPS MID PT 3) SC03 TRUSS NOT BEARING ON BEARING POINT. PROVIDE CITY APPROVED TRUSS ENGINEERING REPAIR 4) TRUSS ?C01M MISSING TRUSS BRACING 5) NAIL DBL STUDS WITH HOLDOWN WITH EDGE NAILING SCHEDULE 6) A04D MISSING H.25 CLIP 7) NO LADDER ACCESS TO ROOF 8) 5/DT1 REQUIRES X BRACE AT 48" ON CENTER |