Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM05646
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
12/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM 4 5 CO3 TRUSSES AT 3RD BEARING POINT 2) IF DAY LIGHT CAN BE SEEN BETWEEN TRIMMERS AND HEADERS, THEY NEED TO BE SHIMMED 3) RECHECK SHEAR AT GARAGE 3 + 12 ON CENTER |
|
12/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF FRIEZE BOARDS PER 7 DT1 2) SHIM TRIMMERS UNDER HEADERS AS NECESSARY 3) REPLACE CUT STUDS MAIN HALLWAY 4) REMOVE SHIMS FROM TRUSSES WHERE INSTALLED AT NON BEARING POINTS 5) TWO TRUSSES BEDROOM 2 NOT SUPPORTED AT BEARING POINTS. 2 NEED SHIMS 6) GARAGE SHEARWALL 7 TO BE NAILED 3 + 12 ON CENTER |
|
12/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GABLE END BRACING NOT PER 6/DTI 2. GARAGE OPENING FOR SHEAR NOT PER 13/DTI MISSING STUD OR TRIMMER 3. GARAGE SHEAR WALL H.D'S NOT INSTALLED 4. NAILS BEING USED ON HOLDDOWNS HARDWARE ARE NOT 016 IN THICKNESS PER SIMPSON GUIDELINES. 5. WIND BRACE EAST WALL -- NO NAILS 6. ALL WINDBRACES NEED 2 NAILS AT BOTTOM & TOP PLATE 7. NEED RSP4 CLIP SW CORNER 8. S.W CORNER OF GARAGE SHEAR WALL NEEDS S.LID DBL STUD. 9. NEED TO SHIM ALL 3PT TRUSSES 10. EDGE BLOCKING AND NOT NAILED 11. SHEAR TRANSFER TO ROOF NOT NAILED 12. TOP PLATE SPLICE MISSING MST37 STRAP TIE PER SD2 |