Permit: T06CM05631

Parcel: 11613201A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/21/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
12/18/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
THE SPECIAL CONDITION FOR THE THREE COMPARTMENT SINK IS THE SANITIZING BOWL. THAT IS THE BOWL THAT IS TO BE PIPED INDIRECT (HEALTH DEPT)
THE WASH AND RINSE BOWL IS TO BE DIRECTLY CONNECTED
12/14/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
SECTION 304 - 2006 UPC
EACH PLUMBING FIXTURE TO BE PROPERLY CONNECTED TO SANITARY SEWER.

SECTION 801.2 - EXCLUSIONS AND CONDITIONS FOR INDIRECT WASTE - DOES NOT INCLUDE 3-COMP SINK
12/12/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ONLY "SPECIAL" WASTE BOWL OF 3-COMP SINK TO BE INDIRECTLY WASTED. OTHER TWO COMPONENTS TO BE CONNECTED DIRECTLY TO SANITARY SEWER.
2. CUT CLEANOUTS DOWN BY ELECTRIC SERVICE PANEL
3. NEED APPROVED PLAN