Permit: T06CM05631

Parcel: 11613201A

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/30/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
10/29/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
USE A FIFTEEN POUND GAUGE IN 1/10 POUND INCREMENTATION FOR THE GAS TEST
10/26/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. ALL VERTICAL PIPING REQUIRES SUPPORT
2. ABS IS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS.
3. PLUMBERS TAPE NOT APPROVED STRAP
4. PIPE MAY BE SUPPORTED TO THE STRUCTURE, BUT NOT BY THE STRUCTURE
5. SITE SEWER COVERED - SUPPLY INSPECTION HISTORY