Permit: T06CM05609

Parcel: 141313360

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM05609

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/20/2007 FRAMING Approved IVRS - Inspection :*
02/16/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OVERSPAN STUD SPACE WEST BATHROOM SHOWER
2) NEED FULL WIDTH SHIM 3 PT BEARING TRUSSES, AT LAUNDRY
3) WINDOW AT FRONT DOOR CLOSER THAN 24" MUST BE SAFETY GLASS
4) WINDOWS IN EAST WALL KITCHEN CRIPPLE ARE SHORT NEED SHIMS
5) G-3 SHEARWALL IN LIVING ROOM, HALL WAY OPPOSITE SIDE NEED TO MOVE H.D. FROM PRESENT LOCATION OR DRYWALL BEHIND INTERSECTING WALL
6) OVER NOTCHED STUDS KITCHEN FOR ROMEX EAST WALL