Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM05609
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/16/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OVERSPAN STUD SPACE WEST BATHROOM SHOWER 2) NEED FULL WIDTH SHIM 3 PT BEARING TRUSSES, AT LAUNDRY 3) WINDOW AT FRONT DOOR CLOSER THAN 24" MUST BE SAFETY GLASS 4) WINDOWS IN EAST WALL KITCHEN CRIPPLE ARE SHORT NEED SHIMS 5) G-3 SHEARWALL IN LIVING ROOM, HALL WAY OPPOSITE SIDE NEED TO MOVE H.D. FROM PRESENT LOCATION OR DRYWALL BEHIND INTERSECTING WALL 6) OVER NOTCHED STUDS KITCHEN FOR ROMEX EAST WALL |