Permit: T06CM05583

Parcel: 138200280


Addresses:

6947 S LUNDY DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM05583

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/27/2008 FRAMING Approved IVRS - Inspection :*
08/14/2008 FRAMING Partial Approval IVRS - Inspection :*
1) EXCEPT BREAK THROUGH
07/08/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
ALL INTERIOR PLATES MUST BE TREATED

1. NAIL PROTECT PEX AT TOP PLATE HOSE BIB
2. PROVIDE 12" CLEARANCE PEX FROM CANS
3. NAIL PROTECT PLUMBING THROUGHOUT
4. GROUT TUB SHOE
5. PROVIDE WATER TEST TO ROOF TOP ABS
POTABLE WATER OK
6. INSTALL & MAKE UP EXHAUST FAN