Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/26/2007 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* I'LL NEED TO SEE THE TUB SET AND CONNECTED NOTE: FURNCO NOT PERMITTED UNDER BLDG. I'LL ALSO NEED TO SEE THE CLOSET FLANGE |
|
| 08/28/2007 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1. VENT COLLAR NOT SCREWED TO WATER HEATER 2. GAS PIPING TO WATER HEATER NOT SECURE (NOTE: ENCLOSURE IS NOT ACCEPTED METHOD OF SUPPORT) 3. REMOVE PLUG COCK ON EXTERIOR WALL 4. PROVIDE LISTING FOR SHOWER VALVE - WHICH IS NOT SECURED NOR IS THE SHOWER HEAD 5. LAVATORY DRAIN - FURNCO NOT PERMITTED - USE A SWEEP FOR THE TURNOUT MAY NOT BE A COMPLETE LIST |
|
| 07/24/2007 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - GAUGE REQUIRED HAS 1/10 PSI INCREMENTATIONS - USE PIPE SUPPORTS ON GAS PIPING BELOW FLOOR, PLUMB AND SECURE RISER AT STOVE - WH DATED 6/2005 REQUIRES PROOF OF PERMIT OR ADD WH REPLACE TO PERMIT. - REPLACE BLACK IRON NIPPS ON WATER CONNECTIONS TO WH - SECURE VENT DRAFT COLLAR TO WH. SECURE VENT CONNECTOR W/GALV SCREWS - SECURE AND SUPPORT GAS PIPING TO WH. INSTALL SEDIMENT TRAP - ALL FIXTURES HAVE BEEN REMOVED, ALL WALL COVERINGS HAVE BEEN REMOVED - ALL PIPE REPAIRS AND FIXTURE INSTALLATIONS REQUIRE INSPECTIONS AS NOTED ON PAGE 3 OF YOUR PLANS - CAP OPEN DRAIN PIPES DURING CONSTRUCTION, SEWER GASSES MAY CONTAMINATE OTHER APARTMENTS. - DO NOT COVER ANY PLUMBING PRIOR TO APPROVAL - TUB AND LAV PIPING REQUIRES REPAIR. - TUB VALVE SHALL BE ANTI-SCALD |