Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* OK FOR FINAL DUCT BOARD MEETS ALL REQUIREMENTS |
|
| 03/20/2007 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1. PLEASE PROVIDE LISTING FOR DUCT BOARD USED WITH AN EVAP COOLER. IF LISTING REQUIRES APPROVAL FROM COOLER MANUFACTURER, PLEASE BE MORE SPECIFIC WITH THE LETTER FROM PHOENIX MANUFACTURING. 2. INSULATE SHEETMETAL SLEEVE ON FURNACE. 3. PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS. EXTEND VENT FROM FURNACE/WATER HEATER 2' ABOVE EVAP. COOLER. EXTEND ANY SEWER VENTS THAT ARE CLOSER THAN 10' TO COOLER. 4. PROVIDE A ROMEX CONNECTOR ON COOLER POWER CORD. |