Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06CM05534
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2007 | PLUMBING - FINAL | Approved | ||
05/24/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* | |
05/23/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. THE POINT OF VENT MAY NOT BE BELOW THE TRAP WEIR 2. THE BACKFLOW DEVICE APPROVED FOR ICE MAKERS IS A WATTS 007 OR EQUAL. |
|
05/22/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* ALL FLOOR SINKS TO HAVE GRATES AND STRAINERS REMOVE ALL CHROME PLATED CLEANOUT COVERS CLEANOUTS TO BE EXTENDED TO FACE OF WALL, COUNTER SUNK TAPPED PLUGS, ETC. CONTINUED NOT READYS WILL RESULT IN A REINSPECTION FEE. REVIEW ALL CORRECTIONS LEFT PREVIOUSLY. |
|
05/21/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CAULK AND SEAL ALL FIXTURES 2. JANITOR SINK REQUIRES ACCESSIBLE CLEANOUT 3. FINISH INSULATION ON HOT PIPING 4. ALL CLEANOUTS TO BE EXTENDED TO THE WALL, WITH COUNTER. 5. SUNK TAPPED PLUG W/C.P COVER AND 5/16" SCREW 6. GRATES AND STRAINERS 7. INDIRECT WASTE PIPING MAY NOT BE COMBINED 8. OVER 5' IN LENGTH TO BE DIRECTLY TRAPPED 9. REQUIRE FULL 1" AIR GAP AT DIPPER WELLS 10. REQUIRE BACKFLOW PROTECTION AT ICE MAKER 11. PRESSURE GAUGE AND THERMOMETER ON WH |