Permit: T06CM05517

Parcel: 117080100


Addresses:

825 S 2ND AV


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T06CM05517

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/12/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
09/06/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- DRAIN CONNECTION TO COIL IS CROSS-THREADED
- DO NOT USE DUCT TAPE TO SUPPORT REFER LINES
- REPLACE THE FLATTENED CONDENSATE TRAP
- PROVIDE A PERMIT FOR NEW WATER HEATER
- DO NOT USE COPPER FLEX ON T&P DRAIN
- CAP OFF THE OLD FURNACE VENT ON THE ROOF
- DO NOT USE WHITE WIRE IN THE ELEC. DISCONNECT
11/29/2006 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
NO ACCESS FOR INSPECTION
NO ANSWER AT DOOR
DISCONNECT FOR AC MUST BE BRACED
11/17/2006 MECHANICAL - FINAL Cancelled CANCELLED PER COTY OF APPLE PLUMBING & COOLING #572-4372