Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM05503
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/30/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
01/23/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* - DWV W/TEST TO TIE IN POINT OK - DOMESTIC WATER PIPING OK BUT IS NOT INSULATED TO PLAN SPECS PROVIDE LETTER OF APPROVAL |
|
01/18/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* ADD ROUGH SOIL TO INSPECTION CARD - SEC. 1014.1.3 DOES NOT ALLOW A DISHWASHER TO BE CONNECTED TO ANY GREASE INTERCEPTOR. - ALSO, SEE SEC. 1014.2 FOR FLOW CONTROL INSTALLATION - VENT TAKE OFF FOR FS AT ICE MAKER SHALL BE ABOVE FLOW LINE OF FIXTURE. USE A 1/6TH BEND OR EQUAL - TRAP ARM DISTANCE IS MIN. 2X DIA. |