Permit: T06CM05491

Parcel: 108253370


Addresses:

2026 E RIVER RD 5

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
02/25/2009 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
03/07/2008 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
11/06/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK INTERIOR ELECTRICAL COVER
10/24/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRECTIONS NOT COMPLETED
10/02/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NEED PROPER CRIMP TOOL FOR CRIMP SLEEVES
2. HAVE OVERFILLED WIRE NUTS
3. PIGTAIL NEUTRALS ON 3-WIRE HOME RUNS
4. MISSING NAIL PLATES - SEVERAL LOCATIONS
5. REMOVE BONDING SCREWS IN SUB-PANELS
6. CHECK RECEPTACLE LAYOUT - 210.52
MAX 6' FROM BROKEN WALL LINE
MAX 12' BETWEEN RECEPTACLES

COUNTER
MAX 24" FROM BROKEN COUNTER ALONG WALL LINE AND BETWEEN RECEPTACLES.